A wafer dual plate check valve (also called wafer butterfly check valve) is a non-return valve that uses two spring-loaded half-discs on a central hinge shaft to prevent backflow. Its compact wafer body installs between two standard flanges with a single set of through-bolts — making it the most space-saving check valve for large-diameter piping systems.
Chuanglan manufactures wafer dual plate check valves in CF8M (316) and CF8 (304) stainless steel as premium range. WCB carbon steel and ductile iron (GGG50) are standard for water / oil & gas service, with EPDM, NBR, Viton or PTFE soft seats for bubble-tight shutoff. We supply DN40–DN700 for DIN EN 1092-1 PN10/PN16 / ANSI B16.5 Class 150 / JIS 10K. For ultra-compact lines see single plate check valve; for sewage / slurry see flanged swing check valve.
The main advantage of a dual plate check valve over single plate or flanged check valves is its balanced design. Two synchronized half-discs each open half the flow area, producing lower pressure drop than a single tilting disc. The spring-assisted closure snaps shut in under 50 ms, eliminating water hammer in high-flow pump stations. This makes the dual plate type the standard choice for large-diameter water, wastewater, power and cooling tower lines. We directly serve EPC contractors and valve distributors in Southeast Asia (Indonesia, Malaysia, Thailand, Vietnam) and the Middle East (Saudi Arabia, UAE, Qatar, Kuwait).
When selecting a dual plate check valve, consider: size (DN40–DN700), pressure rating (PN10 / PN16 / ANSI 150#), body material (ductile iron for water/HVAC, WCB for oil/gas, CF8M for corrosive service), seat material (EPDM up to +120°C for water/HVAC, NBR up to +80°C for oil, Viton up to +200°C for chemical/high-temp oil, PTFE for aggressive chemicals), spring material (SS304 / SS316 / Inconel for sour service), cracking pressure (standard / low / anti-chatter), and installation orientation. Always install a Y-strainer upstream to protect the discs.
Southeast Asia & Middle East Market Notes
Vietnam / Thailand water treatment & pump stations: Ductile iron GGG50 body, EPDM seat, PN10/PN16 — used on large municipal water pump discharge, cooling tower return and raw water intake. Fast closure protects multistage pumps from water hammer during power trip.
Indonesia / Malaysia petrochemical & power plants: WCB body, NBR/Viton seat, ANSI 150# — used on cooling water, fire water and hydrocarbon circuits. Inconel spring for H₂S sour service available.
Saudi Arabia / UAE desalination & oil & gas: CF8M body, SS316 plates, Viton seat, ANSI 150# — used on SWRO high-pressure pump discharge, brine return and gas gathering. 316L for coastal chloride corrosion resistance.
Pump station sizing, water hammer calculation or spring cracking pressure? Send us your pump curve, pipe size and flow rate.
Get Free Sizing Report →Dual Plate vs Single Plate vs Swing vs Lift Check Valve
| Feature | Dual Plate (This) | Single Plate | Swing | Lift |
|---|---|---|---|---|
| Closure time | <50 ms (fastest) | Very fast | Slow (slam) | Medium |
| Face-to-face | 16–75 mm (wafer) | 18–180 mm (wafer) | 150–1350 mm | 130–750 mm |
| Pressure drop | Low | Lowest | Lowest | Highest |
| Water hammer | Best protection | Good | Poor | Medium |
| Handles solids | Limited | No | Yes | No |
| Orientation | Any (spring) | Any | Horizontal only | Horizontal only |
| Best size range | DN100–DN700+ | DN40–DN200 | DN50–DN600+ | DN15–DN300 |
| Best for | Large water pump stations, cooling towers, power plants | HVAC retrofits, tight skids | Wastewater, slurry, sewage | Steam, boiler feed, high-pressure oil |
Technical Specifications
| Type | Wafer dual plate / Butterfly check |
| Size Range | DN40 – DN700 (1.5″ – 28″) |
| End Connection | Wafer type, fits between DIN EN 1092-1 PN10/PN16 / ANSI B16.5 Class 150 / JIS 10K |
| Body Material | CF8M (316) / CF8 (304) — premium; WCB / ductile iron GGG50 on request |
| Plate | SS304 / SS316 half-discs |
| Seat Material | EPDM / NBR / Viton (FKM) / PTFE soft seat |
| Spring Material | SS304 / SS316 / Inconel (sour service) |
| Pressure Rating | PN10 / PN16 / ANSI Class 150 |
| Closure Time | Under 50 ms (water hammer protection) |
| Cracking Pressure | Standard 0.05-0.2 bar; low-cracking 0.02 bar available |
| Installation | Horizontal, vertical (up or down) or inclined |
| Design Standard | API 594 / EN 558 / ISO 5752 |
| Testing | shell & seat pressure test per API 594 |
| Material Certificates | EN 10204 3.1 MTC (material test reports) included |
Material Standards
| Part | Carbon Steel (WCB) | Stainless 304 (CF8) | Stainless 316 (CF8M) |
|---|---|---|---|
| Body | ASTM A216 WCB | ASTM A351 CF8 | ASTM A351 CF8M |
| Plates | SS304 | SS304 | SS316 |
| Spring | SS304 | SS304 | SS316 / Inconel |
| Seat | EPDM / NBR | EPDM / Viton | Viton / PTFE |
Dimension Table — Wafer Dual Plate PN16 (mm)
| DN | L (Face-to-Face) | D (Body OD) | D1 (Bolt Circle) | n-ΦL (Bolts) | H (Height) | W (Width) |
|---|---|---|---|---|---|---|
| 40 | 16 | 95 | 65 | 4-Φ14 | 52 | 70 |
| 50 | 20 | 105 | 75 | 4-Φ14 | 62 | 85 |
| 65 | 20 | 115 | 85 | 4-Φ14 | 72 | 95 |
| 80 | 25 | 135 | 100 | 4-Φ18 | 82 | 110 |
| 100 | 25 | 155 | 120 | 4-Φ18 | 95 | 130 |
| 125 | 30 | 180 | 145 | 8-Φ18 | 110 | 155 |
| 150 | 30 | 210 | 170 | 8-Φ18 | 125 | 180 |
| 200 | 35 | 265 | 225 | 8-Φ18 | 155 | 230 |
| 250 | 40 | 320 | 280 | 12-Φ18 | 185 | 280 |
| 300 | 45 | 375 | 335 | 12-Φ22 | 215 | 330 |
| 350 | 50 | 435 | 390 | 16-Φ22 | 245 | 380 |
| 400 | 55 | 485 | 445 | 16-Φ22 | 275 | 430 |
| 450 | 60 | 545 | 505 | 20-Φ22 | 305 | 480 |
| 500 | 65 | 600 | 560 | 20-Φ22 | 335 | 530 |
| 600 | 70 | 705 | 660 | 20-Φ26 | 395 | 630 |
| 700 | 75 | 810 | 760 | 24-Φ26 | 455 | 730 |
* PN10 drilled pattern, ANSI Class 150 and JIS 10K flange drilling available on request. D1 is the wafer bolt-through hole diameter; actual flange bolt circle matches DIN EN 1092-1 / ANSI B16.5.
Worked Example: DN300 Dual Plate Check for a Hanoi Water Treatment Plant Pump
Project: 120,000 m³/day municipal water treatment plant outside Hanoi, Vietnam. Two parallel raw water pumps (duty + standby), DN300 discharge to the treatment plant header.
Given: DN300 (12″) line, Q = 1,800 m³/h per pump, water at 25°C, PN10, vertical turbine pump. On power trip, reverse flow slams an old flanged swing check, causing loud hammer and pipe vibration.
Step 1 — Calculate velocity:
Pipe area A = π × (0.3/2)² = 0.0707 m². Velocity v = 1800 / (3600 × 0.0707) = 7.07 m/s — high for raw water (target 1.5–3.0 m/s). But this is an existing plant, pump speed fixed; we must protect the pump, not redesign piping.
Step 2 — Why dual plate (not swing or single plate)?
Swing check would slam — closure time 0.5–1.0 s vs reverse flow velocity 7 m/s. Single plate is only rated to DN200 for reliable closure. Dual plate DN300 closes in under 50 ms — two half-discs on spring shaft snap shut before reverse flow builds momentum. Wafer body L=45 mm vs flanged swing L=750 mm — saves space on the pump skid.
Step 3 — Material & seat:
Raw river water, non-corrosive. Specify ductile iron GGG50 body, EPDM seat (suitable for potable water downstream). Standard SS304 spring. No need for CF8M unless chloride level is high.
Step 4 — Installation & protection:
DIN EN 1092-1 PN10 flanges. Install 5 pipe diameters (1.5 m) downstream of pump outlet per API 594 best practice. Add a DN300 Y-strainer upstream to catch river debris (leaves, sticks). On high-velocity applications like this, also recommend an external dashpot / cushioning option for extreme water hammer — tell us your pump shutoff head and we’ll confirm.
4 Common Mistakes When Selecting Wafer Dual Plate Check Valves
Mistake 1 — Using it on sewage or wastewater with solids: The twin half-discs wedge open on rags and fibers, causing leakage. For sewage / palm oil effluent, choose a flanged swing check valve — its single flap swings fully out of the flow path.
Mistake 2 — Ignoring flow velocity (oversized valve): At low velocity (<0.5 m/s) the spring may not fully open the discs, causing pressure drop and chatter. If your minimum flow is low, specify a low-cracking spring (0.02 bar) — don’t just buy a standard spring and hope.
Mistake 3 — Installing too close to pump outlet or elbow: Turbulent flow immediately downstream of a pump causes disc chatter. Keep 5 pipe diameters of straight pipe between pump and check valve; if not possible, specify a double-disc / stabilized design.
Mistake 4 — Forgetting the Y-strainer: Welding slag, scale and Teflon tape score the EPDM seat. A Y-strainer upstream costs 1/10 of the valve and doubles seat life. Always specify both.
Need Sizing Help or a Quote?
Send size (DN), pressure (PN/ANSI), material (304/316L), seat (EPDM/Viton) and quantity — we reply within 24 hours.
Get Free Quote »Applications
Water & Wastewater: Municipal raw water pump discharge, cooling tower return, desalination SWRO pre-treatment.
Power & HVAC: Condenser cooling water, fire water mains, district heating loops.
Oil & Gas: Refinery cooling circuits, storage terminal transfer, gas gathering skids.
Chemical & Palm Oil: Acid/alkali dosing lines, CPO crude palm oil effluent (with Viton seat).
Commercial Terms & Shipping
Payment: T/T 30% deposit + 70% before shipment; L/C at sight accepted for orders above USD 20,000. PayPal for sample orders.
Warranty: 12 months after shipment for material and manufacturing defects. Covers casting defects, seal leakage and material non-conformance. Damage from misuse, improper installation or corrosion beyond specified limits is not covered.
Packaging: Export plywood case (fumigation-free) or seaworthy pallet. Suitable for FCL container and LCL consolidation. Large DN400+ valves on wooden skids.
Shipping Documents: EN 10204 3.1 MTC, pressure test certificate, packing list, commercial invoice. Certificate of origin and BL available on request.
Shipment Port: FOB Ningbo / Shanghai, China. Can also arrange CIF / DAP to your destination port.
Third-Party Inspection: SGS, Bureau Veritas or Intertek pre-shipment inspection supported at your cost.
FAQ
Why dual plate instead of a single tilting disc check valve?
Dual plate valves have two half-discs on a central hinge shaft, so each plate opens to roughly half the flow area. This produces lower pressure drop, faster closure (under 50 ms), and tighter shutoff on large-diameter lines (DN300+). Single plate is shorter and cheaper for small sizes; dual plate dominates large water, wastewater and power plant lines.
Can it be installed vertically (flow up or flow down)?
Yes. The spring-loaded plates close mechanically, independent of gravity. Wafer dual plate check valves work in horizontal, vertical-up, vertical-down and inclined piping — this is why they are the standard choice for pump discharge lines where orientation varies.
How do I stop water hammer on a pump discharge?
Three things: (1) fit a spring-assisted dual plate check valve (closes in <50 ms), (2) install it 3–5 pipe diameters from the pump outlet, (3) consider a variable-speed pump or air chamber. If hammer persists, switch to Viton seat or add an external dashpot / cushioning. Tell us your pipe size and pump flow and we’ll size it.
What cracking pressure do the springs provide?
Standard spring cracking pressure is 0.05–0.2 bar (0.7–3 psi). For very low-flow systems (gravity lines, low-pressure HVAC), we supply a soft spring (0.02 bar). For high-vibration or fluctuating flow, we fit a stiffer spring to prevent chattering.
Is an EPDM seat suitable for potable water / drinking water?
Yes — EPDM seats are suitable for potable water service, the standard choice for municipal water treatment. NBR is fine for oil and general industrial water. Viton is for chemical and high-temperature oil service. We can supply seat certificates on request.
Can it handle H₂S sour service?
Yes — for oil & gas gathering with H₂S, specify CF8M body, SS316 plates and Inconel spring. We can supply ISO 15156 (sour service) compliant materials on request.
MOQ, stock and delivery time?
MOQ is 1 piece. DN40–DN200 in ductile iron / WCB are usually in stock (7 days). DN250 and above, CF8M stainless or Inconel spring takes 15–30 days. ANSI 150# / JIS 10K flange drilling available on request.
What is the warranty period for your valves?
We provide a 12-month warranty after shipment for material and manufacturing defects. This covers casting defects, seal leakage and material non-conformance. Damage from misuse, improper installation or corrosion beyond specified limits is not covered.
📚 Further reading:
• Wafer Check Valve vs Swing Check Valve (2026 Guide)
• How to Select a Wafer Butterfly Valve for Seawater Service
• Butterfly Valve Selection Guide (Size, Pressure, Material)
You May Also Need
Related Technical Guides
Types of Check Valves · How to Choose a Wafer Check Valve · What Is a Wafer Check Valve?
Request a Quote for This Wafer Dual Plate Check Valve
Tell us the size, pressure and quantity you need. We reply within one working day.