Stainless Steel Flanged Gate Valve Rising Stem | Chuanglan Valve

▲

Flanged Gate Valve | Rising Stem OS&Y

Tight shutoff in isolation service — rising stem gives you visible position, no guessing.

Stainless steel 304/316L rising stem gate valve, DN15–DN200, DIN PN16, ANSI 150#

OEM/ODMCustom Manufacturing
ISO 9001:2015Quality Management
Established 2009Valve Manufacturing
7–15 DayLead Time

* Standard lead time depends on order quantity and destination country. 5–10 days to Southeast Asia, 15–20 days to the Middle East.

✍️ Reviewed by Chuanglan Valve Engineering Team · Last updated Oct 2026 · Follow us on LinkedIn
Stainless steel flanged rising stem gate valve OS&Y - Chuanglan Valve

A flanged gate valve is a linear motion isolation valve that uses a wedge-shaped gate to stop or start flow. The rising stem (OS&Y) design makes the valve position visible at a glance — open when the stem rises, closed when it lowers — which is essential for safety and maintenance in industrial piping, oil & gas, power plants and water treatment.

We manufacture rising stem flanged gate valves in stainless steel CF8 (304) and CF8M (316) as our standard range. WCB carbon steel is available for oil/gas and high-temperature steam service. Sizes DN15–DN200 (1/2″–8″), flanged ends per DIN EN 1092-1 PN16 / ANSI B16.5 Class 150 / JIS 10K, PN16 / ANSI 150#. Handwheel operated for DN15–DN150; bevel gear operator for DN200.

Every valve is shell and seat pressure tested per API 598 before shipment. MOQ 1 piece, 7–15 days delivery, ISO 9001:2015. For throttling control instead of isolation, compare our flanged globe valve. For slurry and abrasive media, see our wafer knife gate valve. For general butterfly isolation, see our wafer butterfly valve. get a detailed quotation for your project.

The main advantage of a rising stem gate valve over a non-rising stem valve is the visible stem position. You can immediately see whether the valve is open or closed by looking at the stem height, which is critical for safety in high-pressure and hazardous applications. The outside screw and yoke (OS&Y) design also protects the stem threads from corrosion and wear, extending valve life. Gate valves provide full-bore flow with minimal pressure drop when fully open, making them ideal for isolation service where regular throttling is not required. In pump stations, pair it with a swing check valve to prevent backflow, and protect the valve body with a Y-strainer. We directly serve EPC contractors and valve distributors in Southeast Asia (Indonesia, Malaysia, Thailand, Vietnam) and the Middle East (Saudi Arabia, UAE, Qatar, Kuwait).

Southeast Asia & Middle East Market Notes

Indonesia & Malaysia palm oil mills: Sterilizer steam and condensate — WCB body with Stellite seats for high-temperature steam service, flanged ends for positive isolation.

Saudi Arabia & UAE oil & gas / desalination: CF8M (316) body for coastal chloride environments, ANSI 150# flanges commonly specified for RO pre-treatment and brine discharge.

Vietnam & Thailand water treatment: CF8 (304) body with brass seats, PN16 flanged ends, handwheel operated — the most cost-effective choice for municipal water distribution networks.

Not sure whether you need gate, globe or ball valve?

Get Free Sizing Report →

Technical Specifications

Size RangeDN15 – DN200 (1/2″ – 8″)
End ConnectionFlanged ends per DIN EN 1092-1 PN16 / ANSI B16.5 Class 150 / JIS 10K
Body MaterialCF8M (316) / CF8 (304) — standard; WCB carbon steel available on request
Gate / SeatSS316 + Stellite (316L) / SS304 + Stellite (304) / Stellite + SS13Cr (WCB)
StemRising stem (OS&Y), SS316 / SS410 / SS630
Pressure RatingPN16 / ANSI 150#
Temperature Range-29°C ~ +425°C (WCB) / -10°C ~ +200°C (CF8M)
HandwheelDuctile iron, DN15–DN150; bevel gear for DN200
Applicable MediaWater, steam, oil, gas, chemical, wastewater
Testingshell & seat pressure test per API 598
Material CertificatesEN 10204 3.1 MTC (material test reports) on request
StandardAPI 600, BS 1414, EN 1171 (face-to-face per EN 558 Series 14)

Gate vs Globe vs Ball Valve — Which One to Choose?

FeatureGate ValveGlobe ValveBall Valve
Best forFull open / full closed isolationThrottling / regulationQuick shut-off, tight shut-off
Flow directionBidirectionalUnidirectional (flow up through plug)Bidirectional
Pressure dropVery low (full bore)HighLow (full bore)
OperationMany turns (slow)Many turns (slow)90° quarter turn (fast)
Throttling OK?No (seat erosion)Yes (designed for it)Limited (only low velocity)
Typical sizeDN15–DN1200+DN15–DN300DN8–DN300
Our productFlanged Gate ValveFlanged Globe ValveFlanged Ball Valve

Dimension Table — DIN EN 1092-1 PN16 (mm)

Face-to-face per EN 558 Series 14 (long pattern). ANSI B16.5 Class 150 / JIS 10K flanges available on request — specify when ordering.

DNL (Face-to-Face)D (Flange OD)K (Bolt Circle)d (Raised Face)c (Thickness)n-ΦL (Bolts)H (Open Height)Do (Handwheel)
15130956545134-Φ14185120
20150105755813.54-Φ14200120
251601158568144-Φ14225140
3218014010078144-Φ18275160
402001501108814.54-Φ18295200
5025016512510215.54-Φ18350220
65265185145122164-Φ18370240
80280200160138178-Φ18390280
10030022018015818.58-Φ18435300
125325250210188208-Φ18520320
15035028524021221.58-Φ22610350
2004003402952682512-Φ22785400

H (open height) and Do (handwheel diameter) are reference dimensions — actual values depend on gearbox and bonnet design.

Worked Example: Selecting a DN80 Rising Stem Gate Valve

Project: Cooling water isolation valve for a pharmaceutical plant in Bangkok, Thailand.
Given: DN80 flanged gate valve, water at 35°C, PN16, DIN EN 1092-1 PN16 flanges required, media is treated cooling water.

Step 1 — Determine size:
Flow rate Q = 80 m³/h, pipe DN80. Pipe area A = π × (0.08/2)² = 0.00503 m².
Velocity v = 80 / (3600 × 0.00503) = 4.42 m/s — slightly high for cooling water (recommended 1.5-3.0 m/s). Consider upsizing to DN100 if pressure drop matters.

Step 2 — Select material:
Treated cooling water in Bangkok — CF8 (304) body with EPDM seat is sufficient. 316L not needed unless seawater or chlorinated service.

Step 3 — Select flange standard:
End user specified DIN EN 1092-1 PN16 flanges. We supply valve with PN16 drilled flanges: D=200 mm, K=160 mm, 8×Φ18 bolt holes, raised face d=138 mm, thickness c=17 mm. Face-to-face L = 280 mm per table above.

Step 4 — Select actuation:
Valve is used for annual maintenance isolation, not daily operation. Handwheel is sufficient. Add bevel gear only if the valve is located in a hard-to-reach position.

4 Common Mistakes When Selecting Gate Valves

Mistake 1 — Using a gate valve for throttling: Gate valves are designed for fully open or fully closed isolation. Partially opening causes seat erosion, wire-drawing and vibration. For throttling, use a globe valve.

Mistake 2 — Specifying WCB body for seawater: WCB carbon steel corrodes rapidly in chloride environments. Always use CF8M (316) for desalination, coastal and marine applications.

Mistake 3 — Choosing non-rising stem for above-ground safety service: NRS stem is hidden inside the bonnet — you cannot visually confirm open/closed position. For safety-critical isolation, always specify rising stem (OS&Y).

Mistake 4 — Forgetting gasket and bolts: Flanged gate valves require new gaskets and bolts. We supply matching stainless steel flanges, gaskets and bolts — specify 304 or 316L.

Need Sizing Help or a Quote?

Send size (DN), pressure (PN/ANSI), material (304/316L), seat (EPDM/Viton) and quantity — we reply within 24 hours.

Get Free Quote »

Applications

Oil & Gas: Refineries, pipelines, tank farms, gathering stations.
Power Plants: Boilers, cooling water, steam systems, condensate.
Water Treatment: Municipal water, wastewater, irrigation, RO desalination.
Chemical: Corrosive fluid, acid & alkali service, pharmaceutical processing.

Quality Control

1. Raw material inspection (spectrometer test for chemical composition)
2. CNC machining & dimensional inspection
3. Shell pressure test (1.5× PN rating, 60 seconds hold)
4. Seat pressure test (1.1× PN rating, bubble-tight acceptance per API 598)
5. Final visual inspection, torque test & packing

Commercial Terms & Shipping

Payment: T/T 30% deposit + 70% before shipment; L/C at sight accepted for orders above USD 20,000. PayPal for sample orders.

Warranty: 12 months after shipment for material and manufacturing defects. Covers casting defects, seal leakage and material non-conformance. Damage from misuse, improper installation or corrosion beyond specified limits is not covered.

Packaging: Export plywood case (fumigation-free) or seaworthy pallet. Suitable for FCL container and LCL consolidation.

Shipping Documents: EN 10204 3.1 MTC, pressure test certificate, packing list, commercial invoice. Certificate of origin and BL available on request.

Shipment Port: FOB Ningbo / Shanghai, China. Can also arrange CIF / DAP to your destination port.

Third-Party Inspection: SGS, Bureau Veritas or Intertek pre-shipment inspection supported at your cost.

FAQ

What is the difference between rising stem (OS&Y) and non-rising stem gate valves?

Rising stem (OS&Y) valve shows the open/closed position visually by stem height — required for safety in high-pressure and hazardous service. Non-rising stem (NRS) valve has the stem inside the bonnet — more compact, ideal for underground or space-limited installations.

Can gate valves be used for throttling flow?

No. Gate valves are designed for fully open or fully closed isolation service only. Partially opening a gate valve causes seat erosion, vibration and noise. For throttling control, use a globe valve or control valve.

What is the pressure and temperature rating for WCB body?

ASTM A216 WCB carbon steel is suitable for -29°C to +425°C, with PN16 / ANSI 150# pressure rating. For higher temperatures or cryogenic service, specify WC6, WC9 or LCC body material.

Do you provide gear operator or electric actuator for large sizes?

Yes, for DN200 and above we supply bevel gear operators as standard, and can mount electric or pneumatic actuators for automated operation.

What certifications do your gate valves come with?

Each valve comes with EN 10204 3.1 MTC (material test report), pressure test certificate and ISO 9001:2015 quality certificate. CE marking and third-party inspection (SGS / Bureau Veritas / Intertek) are available on request.

What is the minimum order quantity and delivery time?

MOQ 1 piece. Standard sizes (DN15–DN100) are in stock and ship within 7 days. Custom sizes or materials take 15–30 days depending on quantity.

Can you supply 316 stainless steel gate valves for seawater service?

Yes, CF8M (316) body with SS316 gate and Stellite seat is recommended for seawater, desalination and coastal chloride environments. We also supply matching lift check valves and stainless steel flanges.

What is the warranty period for your valves?

We provide a 12-month warranty after shipment for material and manufacturing defects. This covers casting defects, seal leakage and material non-conformance. Damage from misuse, improper installation or corrosion beyond specified limits is not covered.

📚 Further reading:
• Butterfly Valve Selection Guide (Size, Pressure, Material)
• Wafer Check Valve vs Swing Check Valve (2026 Guide)
• How to Select a Wafer Butterfly Valve for Seawater Service

You May Also Need

Request a Quote for This Flanged Gate Valve

Tell us the size, pressure and quantity you need. We reply within one working day.








    Need a Custom Valve or Fitting?

    Send us your specs: pressure, size, material and quantity — our engineers will reply within 24 hours with a detailed quotation. MOQ 1 piece.

    Southeast Asia: Indonesia, Malaysia, Thailand, Vietnam, Singapore, Philippines · Middle East: Saudi Arabia, UAE, Qatar, Kuwait, Oman, Bahrain · Other: the Americas, Europe, Africa, Australia

    FOB Ningbo / Shanghai · 5–10 days to Southeast Asia · 15–20 days to the Middle East · We reply within 24 hours (usually same business day)

    Commercial terms: T/T 30% deposit + 70% before shipment, L/C at sight · export plywood case / fumigation-free pallet · 12 months warranty after shipment for material and manufacturing defects · EN 10204 3.1 MTC + API 598 test report + packing list + commercial invoice with every order · SGS / Bureau Veritas / Intertek pre-shipment inspection available

    Get Free Quote »
    Disclaimer: This guide is for general engineering reference only. Final valve selection, sizing and installation must follow the manufacturer data sheet, the project P&ID and the applicable code (EN 1092, ASME B16.5, ASME B16.34, EN 10204 3.1). Where this article and those documents differ, the documents govern.